THIS PRODUCT IS DISCONTINUED. The Conductivity Analyzers -4620 wall mount and -4625 panel mount are user-programmable analyzers
designed for use in Utilities, Semi-conductor, Chemical Processing, and
Pharmaceutical industries. |
![]() |
||
| FEATURES | BENEFITS | |
| Ultra-Pure Compensation | Ultra-pure water temperature compensation insures accuracy at conductivities of less than 1 NS/cm. | |
| Wide Measurement Range | Wide range of measurement covers applications from ultra-pure water to liquids with conductivity up to 10,OOONS/cm. | |
| Universal Scaling | Incorporates universal scaling to provide the best resolution for your application requirement. Measurement range can be scaled to NS/cm, pS/m, mS/cm, mS/m, Mohm-cm, TDS and ppm. | |
| m On-Line Diagnostics | Comprehensive diagnostics continuously verify analyzer operation of the entire sensing loop with built-in software protection. |
![]() |
![]() |
![]() |
![]() |
||||
FLOW
CELL MODEL 2045 |
SCREW-IN
MODEL 2077 |
SCREW-IN
MODEL 2078 |
WITHDRAWABLE
CELL - MODEL 2085 |
||||
| Cell
constant available: |
0.1
or 1.0 |
0.1
or 1.0 |
0.05
or 0.1 |
0.05
or 0.1 |
|||
| Type: | Flow-line |
Screw
type |
Screw-in |
Withdrawable |
|||
| Cell Body: | Loaded
epoxy resin |
Loaded
epoxy resin |
316
St. Steel |
316
St. Steel |
|||
| Electrode Matl.: | Carbon |
Carbon |
316
St. Steel |
Naval
brass & 316 St Steel |
|||
| Connections: | Threaded
NPT |
Threaded
NPT |
Threaded
3/4" NPT |
Use
with Model 2089 valve assembly |
|||
| Maximum press.: | 100
psi |
100
psi |
150
psi |
150
psi |
|||
| Maximum temp.: | 194°F
(90°C) |
194°F
(90°C) |
230°F
(110°C) |
230°F
(110°C) |
|||
| NOTE:
To select the most suitable cell constant for the desired range use the
following criteria: Minimum range 10 x the cell constant Maximum range 10,000 x the cell constant e.g. cell constant k=0.1 Minimum range = 10 x 0.1 = LOONS/cm Maximum range = 10,000 x 0.1 = 1000NS/cm For ultra-pure water applications (less than LOONS/cm) a cell constant of 0.05 must be used. |
|||||||
Display Information: |
Error
due to power supply variation: Less than 2% for +6% - 20% variation from nominal supply voltage. Insulation Line to ground: 2kV r.m.s. Outputs and Set Points Number of relays/set points: Two. Relay contacts: Single pole changeover. Rating 250V a.c. 250V d.c. max. 3A a.c. 3A d.c. max. Loading (non-inductive) 750VA 30W max. (inductive) 750VA 3W max. Insulation: 2kV r.m.s. contacts to earth (ground). Number of set points: Two. Set point adjustment: Programmable. Set point hysteresis: ± 1 % fixed. Local set point annunciation: Red L.E.D. Retransmission: Number of retransmission signals: One fully isolated. Output current: 0 to 10mA, 0 to 20mA or 4 to 20mA programmable. Accuracy: ±25% f.s.d. or ±0.5% reading. Resolution: 0.1 % at 10mA, 0.05 at 20mA. Maximum load resistance: 750 ohm (20mA max.). Serial communication: RS485 (optional extra). |
|||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||