THIS PRODUCT IS DISCONTINUED and has been replaced with our NEW Dissolved Oxygen Analyzer Aqualyzer® 9061 or Dissolved Oxygen Analyzer Aqualyzer® 9062. The Waltron
Series 9060 Dissolved Oxygen Analyzer is a state-of-the-art microprocessor-based
instrumentation package developed specifically for use in measuring low
and high concentrations of dissolved oxygen in the power (fossil, nuclear
and cogeneration), desalination and petrochemical industry. |
![]() |
||
| FEATURES | BENEFITS | |
| Disposable Sensor | No maintenance. Reduced operating and maintenance cost. | |
| Automatic On-Line Calibration | Automatically air calibrates on-line every 7 days. True auto-cal. | |
| Sensor Thermal Protection | Temperature bypass protects sensor from extreme temperatures. | |
| Constant Head Flow Assembly | Eliminates inaccuracies due to changes in sample flow and pressure. | |
| Comprehensive Self Diagnostics | Automatically evaluates electronic and electrode output performance. | |
| Two-Year Sensor Warranty | Lowest cost of ownership in the industry with proven on-line performance. |
| The Dissolved Oxygen Analyzer should be installed where the following conditions can be maintained: | ||
| Sample
Flow 100 to 300 ml/min. |
Sample Temperature |
|
| Ambient
Temperature 32 - 131° F (0 - 55° C) |
Pressure 5 - 100 psig |
|
| Composition Filter to 60 micron, free of film forming compounds |
||
| Range: 0-20 ppb, 0-200 ppb, 0-2 ppm and 0-20 ppm with automatic range change and four sets of normally open contacts, one of which closes for remote range indication. Accuracy: Precision: Temperature Compensation: Calibration: Alarms: Dimensions: |
Weight: 50lbs. Current Outputs: Response Time: Atmospheric Pressure
Compensation: Thermal Protection: Power: Degree of Protection: |
|
The autocalibration is achieved by draining the flow cell and exposing the probe to air. This is carried out automatically on-line for three minutes and involves no manual operation. An automatic calibration check is performed every 7 days. Calibration can be initiated at any time manually by depressing the Manual Calibration Pushbutton on the instrument panel. |
|
| The Liquid Handling System features an air-tight flow cell housing a disposable solid state no maintenance DO sensor. The flow cell is self cleaning, preventing air bubble entrapment and minimizing particle deposition. The sensor is a galvanic membrane covered three electrode electrochemical cell. The sensor can be easily unscrewed from its holder, discarded, and replaced, an operation taking less than 60 sec. to perform. |
|