8242 Phosphate monitor has been designed with the greatest simplicity
in mind. Developed as continuous monitor offering wide dynamic ranging,
the 8242 features a carefully designed liquid handling section,
which reduces maintenance to an absolute minimum. Cost effective
ownership is insured through the utilization of microprocessor-based
electronics that offer automatic calibration, continuous sample
monitoring and programmable multi-stream switching. |
|
||
| FEATURES | BENEFITS | |
| Programmable Auto Zero Facility | Automatically compensates for sample color and reagent background silica. True auto zero. | |
| Unique Heated Block Assembly | Maintains full temperature control over chemical reactions and optical measurement system. | |
| Fully Programmable Multi-Stream Option | Six stream capability maximizes operational control for monitoring a number of samples from different locations | |
| Dynamic Mixing and Temperature Control | Insures full mixing and reproducible control of samples and reagents guaranteeing complete chemical reaction | |
| Low Maintenance Sample Pump | Annual pump tubing replacement maximizes on-line availability | |
| Microprocessor-Based High Specification Electronics | Controls all measurement and management functions, eliminating operator attention after set-up | |
| Comprehensive Self-Diagnostics | Minimizes operator error and optical source maintenance needs | |
| Continuous Uninterrupted On-Line Measurement Cycle | Insures optimum speed of response |
| The monitor should be installed where the following conditions can be maintained. | ||
| Sample
flow: 5 to 750ml/min. Suspended
solids: Ambient temperature: |
Sample
temperature: Within the range 5 to 55°C. Reagent solutions: Calibration
solutions: |
|
Range: Repeatability: Reproducibility: Response
time: Chemical
drift: Control temperature
range: Temperature
resolution: Degree of
protection: Security
code: |
Current
outputs: SINGLE STREAM OR MULTISTREAM As standard, two isolated current outputs 0 to 1, 0 to 10, 0 to 20, or 4 to 20mA, software selectable. Range independently selectable over the full range of the monitor. Maximum voltage load is 15V. Computer
interface: Alarms: MULTISTREAM Concentration
alarm adjustment: Calibration: Power supply: Isolation
voltage: |
|
Displays: Status indication: |
||